Design Criteria Earthsafe Environmental Model ES10PC
Aerated Wastewater System
Non Conventional
Loading
10 persons at the following rates per person day
- 150 litres per day
- 70 grams BOD5
- 70 grams suspended solids
- 15 grams total nitrogen
- 2.5 grams total phosphorous
Anaerobic Chamber
- 3247 litres
- Minimum size allowed based on AS1546 is 24 hours retention and 3 years sludge retention + 3050 litres
- Divided into tow compartments – primary 1 = 66% capacity, primary 2 = 34% capacity
Aerobic Chamber
- 2852 litres which is 45.6 hours detention or 285.2 litres per person
- Media surface area 200m2/m3 – refer attached specification sheet
- Based on 8.42 grams BOD5 removed per m2 surface area
Freeboard
- 1000 litres at 250mm below top of insert
- 1600 litres total freeboard prior to over flow into chlorination and pump well chamber
- Based on 8.42 grams BOD5 removed per m2 surface area
Air Supply
- Model Hiblow HP80 Blower or equivalent – refer attached specifications
- Minimum D.O. Level 2.0mg/L
Clarifying Chamber
- 0.5289m2 surface area
- 460 litres – 7.36 hours retention
- Sludge hopper minimum 55degrees to horizontal
Disinfection Chamber
- 165 litres
- Based on maximum flow 5L.P.M at high flows. Contract time will be 33 minutes
- Adjustment cap to increase or decrease chlorination
- 2 chlorine canisters standards with space to add third canister if required
- Maintains free chlorine residual of 0.2 to 2mg/L
- Minimum 4 months chlorine storage
Irrigation Chamber
- 165 litres
- Dab600 irrigation pump or equivalent minimum – refer attached specification
Concrete Tanks
- Must be accredited by Director general of NSW Health
Other
- All components stainless steel or other non corroding material
- Plastic and perishable components will retain their integrity under normal operating conditions
- All components to be firmly fixed to withstand loads encountered during transpiration, installation and normal operation
- All mechanical and electrical equipment not designed for submergence will be above maximum water level of system
- All equipment suitable for continuous and intermittent operation
Alarm System
- Audible and visual alarms with muting facility for the audible alarm
- Alarm indication for electrical, blower and pump failure
- Mute switch will reset after 24 hours
- Alarm will be visible from residence
- All wiring in accordance with AS3000 “Electrical Installation – Buildings Structures and Premises”
Noise
- Maximum 55 DB (A) at 1 meter